Sales Department |
|
|
| |
8610-68436601 |
|
| |
8610-88552051 |
|
| |
8610-88552651 |
|
|
Fax |
|
| |
8610-68436080-813 |
|
|
Our country is defined as “Water-deficient country” by United Nation, one possible method to solve this problem is save water. Large Caliber water meter is a management system for medium to heavy usage of water. In the past, many problem exist because of the poor technology and manual operation.
NingBo LongKang Intelligent Water Meter Company start the research on water-controlled substitute from 1999, received support from Italy Bermad Company in 2000 to open up DJY series water-controlled valve. More than that, the Large Caliber IC card intelligent water meter is opened up on the basis of that valve.
The company use the technique of isolation between card and stand to separate the stand from the table, so that the we can operate outside the meter working place, the company also imply the technique of portable machine on the large caliber water meter, achieve the communication between single-piece machine and double-piece machine, so that distant control through the LCD screen can be successful.
Exterior implement:
The large caliber IC card intelligent water meter opened up by NingBo LongKang Intelligent Water Meter Company has compact and coordinate structure. The products are reliable, stable, and they have a long life-span. The specials are:
Use logical encryption, one password for each table, non-decipherable.
Use stable hardware and software, solve interference and high power problem.
Use import pith material, which make the battery work for over 5 years.
Reliable current checking function, can set an automatically closure of valve when low power to cut the water circuit.
The water meter solve the traditional valve leakage problem.
When the sum of purchasing amount in card and the usable amount in meter exceeds the maximum amount, the meter will automatically reject the sum to avoid the stock up of water.
When the usable amount equals alarming amount, the meter will be automatically switched off and alarmed, the user need to insert the user card to continue.
When the usable amount in meter has used up, the meter will be automatically switched off and shown “clear bill”, “usable amount 0” and so on.
When the current is too low, the meter will be automatically switched off and shown “change batteries”, the users must change batteries to switch on the meter again.
Item |
Functions & Technology requirement |
Normal function |
Display |
Function |
Limitation to current input, water remain, accumulated amount, clear bill, switch on/off and so on. |
Number |
Maximum accumulated amount is 9999.9m 3 |
Control |
Usage |
When the usable amount equals alarming amount, the meter will be automatically switched off and alarmed, the user need to insert the user card to continue. |
Low battery |
When the battery current is lower than the preset value, the system will show a switch-off warning. The use need to insert user card to continue. |
Battery enquiry |
The system will automatically screen the circuit to see if it is properly set. |
Burglarproof & snap-proof |
When the signal circuit is cut, the system will be shut down automatically and shown “attacked”, the user cannot recover the problem. |
Antimagnetic |
When there is a magnetic attack, the system will be shut down automatically and on when the magnetic substance is away, the user need to insert user card to continue. |
Moisture-proof stand |
Moisture has no effect on the stand and the system will check if IC card is working properly. |
Self protection battery & valve |
Meter will be automatically switch on and off once for each month. |
Set limitation |
When the sum of purchasing amount in card and the usable amount in meter exceeds the maximum amount, the meter will automatically reject. |
Over-zero treatment |
When the valve is not functioning, the normal counting and over-zero counting will not be affected. User need to feedback to the computer software for processing. |
Pulse Moisture-proof |
The signal path will not be affected even they are attacked by moisture. Data will not be lost. |
Self checking |
Self check for mistakes in initializer, storage, card and so on. |
Patrolling & Checking |
Patrolling will be done when receiving any attacks, if the attack is over during patrolling, the system will restore to normal. |
Usage |
Multi-meter card |
One client can use cold, hot and purified water meter. |
Distant control |
The portable machine can function away from the table( ≤10m ) to check the table. |
Checking, retrieval data |
When the meter is broken and needed to be changed, The checking and retrieval card can transfer the history to the computer. |
Initialization |
The initialization card can clear all history and set all parameters again. |
Checking card |
When the meter is not function properly, the checking card can test if the system is working. |
Reissue |
Cards can be reissued when the users lost their cards |
|