In civilized management, the resident region managed by the water supply department is diverse. The data management cannot be united and that is not convenient to the management staff. At the same time, the requirement to real-time and in-time is becoming important.

NingBo LongKang Intelligent Water Meter Company has opened up a distant meter taking system, which canceled IC card usage and recorded data in the storage of table at any moment, then made use of centralizer to take the readings. The meter has storage and batteries, even the communication circuit breakdown, it can still work for 5 years. When the communication circuit has recovered, the history can be completely written to the centralizer. One centralizer can carry 128 water meter, which greatly lowered the workload of operators. There are three methods for the transition from centralizer to terminal, they are portable machine, RS-485 wired method, GPRS wireless method. The management department can decide upon their own to choose one or more of the above methods. The system lower the difficulties of collecting data, increase the stability of products.

Exterior implement:

The distant meter taking system opened up by NingBo LongKang Intelligent Water Meter Company has compact and coordinate structure. The products are reliable, stable, and they have a long life-span. The specials are:

•  Use stable hardware and software, solve interference and high power problem.

•  Use import pith material, which make the battery work for over 5 years.

•  Reliable voltage checking, can generate warning when the power level lower than preset value.

•  Management department can choose from the three methods to collect data, and analyzed by the management software.

•  Internal storage and batteries, to ensure proper work when circuit has brokendown.

Function table:

Item

Functions & Technology requirement

Control

Insufficient batteries

Voltage checking can generate warning when the power level lower than preset value

Burglarproof & snap-proof

When circuit was cut, the system will automatically record the number and time

Antimagnetic

When system was attacked by magnetic field, the system will automatically record the number and time

Moisture-proof

The system can still receive and send signals properly even it was attacked by moisture

Usage

Data taking

The system can take history or real-time data for accumulate usage and monthly usage

Working status

Real-time taking the working status, the number and time of the attacks

Timing

The centralizer will check the timing monthly

Storage

Internal storage and batteries, to ensure proper work when circuit has brokendown


 